1. Use
Connect the power supply and equipment, to the controller power supply, as measured temperature is displayed, press the SET button, the display temperature flashes, press “+” “-” to set the desired temperature (hold down the button 5 seconds more quickly lift). After setting press SET to confirm return, then the controller according to the set temperature automatically execute the relay off!
nbsp
2. Indicator, LED Status Description
Indicator: indicates relay is closed, Off means the relay has been disconnected;
nbsp
Digital: Displays the sensor 888 is open, follow the instructions to connect the sensor;
Show HHH for the excess of the maximum temperature of the measuring range, the thermostat will be forced off the relay;
Display L L L of the measuring range of the lowest temperature, the thermostat will be forced off the relay;
Display – – – high temperature alarm, thermostat will forcibly disconnect relay;
nbsp
3. Parameter Function
nbsp
Press SET button for 5 seconds to enter the main menu settings, press the “+” “-” Switching P0-P8, long press SET to confirm or automatically 10 seconds after no key operation of the controller to return.
nbsp
nbsp
P0 refrigeration, heating mode:
In the main menu interface P0, press the SET key to enter setup, press “+” “-” to switch to heating mode [H] [C] for the cooling mode, press SET to return, long press SET or 10 seconds without button operation control automatically confirm completion.
nbsp
[C] under cooling mode: Measured value ge set point + hysteresis, relay; measured value le set point, the relay off;
[H] Under heating mode: Measured value le set point – hysteresis, relay; measured value ge set point, the relay off;
nbsp
nbsp
P1 hysteresis setting:
In the main menu interface P1, press the SET button to enter the hysteresis settings, press the “+” “-” to set hysteresis of 0.1 to 30, press SET to return after the completion of a long press SET or 10 seconds without button operation controller automatically confirm completion.
nbsp
Cooling mode: When the measured temperature ge set value + return difference, relay, refrigeration starts; when the temperature measured value le set value, the relay off, refrigerator off.
For example: the environment 30degC, 25nbspnbspnbspdegCnbspnbspnbspnbspis set, hysteresis is set to 2nbspnbspnbspdegCnbspnbspnbsp, after power relay closed refrigeration starts, when the cooling to 25nbspnbspnbspdegCnbspnbspnbsp, the relay off cooling off, this time due to cooler have disconnected the temperature began to rise, when the set value rose to 27nbspnbspnbspdegCnbspnbspnbspnbsp(set point + return difference) relay closes when the chiller is started again, and so forth loop between the control temperature 25-27nbspnbspnbspdegCnbspnbspnbsp.
nbsp
Heating mode: when the temperature measured value le set value – the difference back, relay, heater start; when the temperature measured value ge set value, the relay is switched off, the heater is turned off.
For example: 10nbspnbspnbspdegCnbspnbspnbspnbspenvironment for the setting is 25nbspnbspnbspdegCnbspnbspnbsp, hysteresis is set to 2nbspnbspnbspdegCnbspnbspnbsp, after power relay closed the heaters, when heated to 25nbspnbspnbspdegCnbspnbspnbsp, the relay off the heater turned off, this time because the heater has been disconnect the temperature began to fall, down to the current set point 23nbspnbspnbspdegCnbspnbspnbspnbsp(set-point – return difference), the relay is closed heater starts again, and so forth cycle to control the temperature between 23-25nbspnbspnbspdegCnbspnbspnbsp.
nbsp
nbsp
P2 highest temperature setting limit:
To avoid misuse of others led to the set temperature is too high risk, the highest setting of the thermostat capping defining the control thermostat setting range maximum temperature set point.
In the main menu interface P2, press the SET key to enter setup, press “+” “-” to set up the set temperature (maximum 110), press SET to return after the completion of a long press SET or 10 seconds without button motion controller automatically confirm completion.
For example: P2 is set to 60nbspnbspnbspdegCnbspnbspnbsp, the highest temperature measured only 60nbspnbspnbspdegCnbspnbspnbsp, when the temperature rises to 60nbspnbspnbspdegCnbspnbspnbsp, the digital tube displays “H H H”, the relay forcibly disconnected. If you want a higher temperature set point temperature to expand the scope, you need to adjust the upper limit set value.
nbsp
nbsp
P3 set minimum temperature limit:
To avoid misuse of others lead to the occurrence of ice blocking temperature is too low, the lowest of the thermostat set lower limit function, defining the scope of the thermostat setting controls the minimum temperature set point.
In the main menu interface P3, press the SET key to enter setup, press “+” “-” set the minimum temperature can be set (minimum -50), press SET to return after the completion of a long press SET or 10 seconds without keystroke controller automatically confirm completion.
For example: P3 is set to -20nbspnbspnbspdegCnbspnbspnbsp, the lowest temperature of -20nbspnbspnbspdegCnbspnbspnbspnbspcan be measured, when the temperature was lowered to -20nbspnbspnbspdegCnbspnbspnbspnbspafter, LED displays “L L L”, the relay forcibly disconnected. If you want to lower the temperature set point temperature to expand the scope, you need to adjust the setting value lower limit.
nbsp
nbsp
P4 temperature correction:
When the measured temperature and the standard deviation of temperature or because the user hardware has special needs, you can use this function to correct temperature corrected before correction + = temperature correction effective range of -7.0 to 7.0 (unitnbspnbspnbspdegCnbspnbspnbsp).
In the main menu interface P4, press the SET key to enter setup, press “+” “-” to set the correction value, press SET to return once completed, long press SET or 10 seconds without button operation controller automatically confirm completion.
For example: Normal display 25 degrees; temperature correction is 0:00 Show 25 degrees; temperature correction display 26.5 1.5 degrees; temperature correction -1.5 23.5 degrees when displayed.
nbsp
nbsp
P5 delay start time (unit: seconds):
When refrigeration or heater work required delay can be turned on delay function to protect the life of the equipment.
In the main menu interface P5, press SET key to enter setup, press “+” “-” Setting the delayed start time (unit: seconds), the delay time in the range of 0-600 seconds, press SET to return after the completion of a long press SET or 10 seconds without button operation controller automatically confirm completion.
nbsp
Cooling mode: the first power on, if the current temperature ge set value + return difference when the chiller does not start cooling immediately after the need to run the set delay time to start.
Heating mode: the first power on, if the current temperature le set value – the difference between the time back, the heater does not start heating immediately after the need to run the set delay time to start.
nbsp
Downtime cooler or heater starts between two adjacent delay start time is greater than the set value, cooling starts immediately. Shutdown cooling or heater adjacent lapse between two starts is less than the delay start time setting, start again after the need to run chillers complete set delayed start time for the device to start. Delay time is counted down instantly. Delay start is set equal to zero off delay function.
nbsp
For example: cooling mode set the delay to 60 seconds, if the current temperature ge set value + return difference when the thermostat start delay after power, after 60 seconds, turn cooler. When you reach the desired temperature of the refrigerant is stopped, then the start time, the next time the cooling starts, if after a time delay set by the cooler work immediately or to wait for the end of the timer to work.
nbsp
P6 Buzzer switch (this function is invalid)
nbsp
P7 temperature alarm function:
In the main menu interface P7, press SET key to enter setup, press “+” “-” to set the high temperature alarm temperature setting range is 0-110nbspnbspnbspdegCnbspnbspnbspnbspor OFF to turn off this feature (factory default is 50nbspnbspnbspdegCnbspnbspnbsp). Upon completion press SET to return, long press SET or 10 seconds without button operation controller automatically confirm completion.
When the temperature reaches the set value of the high temperature alarm, digital display – – – simultaneously forced off the relay. When setting has been pressing “-” key, the setting value is reduced to 0, then click the “-” key to display “OFF”, at which time the function is off, the high temperature alarm function is invalid.
nbsp
P8 restore factory settings:
Some man-made causes internal thermostat setting confusion, one by one to set the time-consuming, then use this function to restore the factory settings.

In the main menu interface P8, press SET key to enter setup, press “+”, “-” is set to [H], press SET to return after the completion of a long press SET or 10 seconds without button operation controller automatically confirm complete recovery factory settings. (Another way: In the off state, while holding down the “+” and “-” button, then on, all of the above parameters back to factory default settings.)

nbsp

nbsp

W1209WKnbsp Specifications:

Temperature measurement range:-50Celsius-110Celsiusnbsp

Temperature 0.1,other paragraph 1nbspCelsiusnbsp
Accuracy:0.1Celsiusnbsp
Return difference accuracy:0.1Celsiusnbsp
Refresh rate:0.5snbsp
High temperature protection:0-110Celsiusnbsp
The input voltage:DC12Vnbsp
Measurement input:NTC (10K 0.5%) waterproof type sensornbsp
Output:10 a relay all the waynbsp
Environmental requirements:-10Celsius,-60Celsiusnbsphumidity 20%-85%nbsp
Size:48mm(length) x 29mm(width) x 32mmnbsp
Hole size:46 x 26.5mm

 

 

Informação adicional

Peso 0.010 kg
Dimensões 5 × 5 × 5 cm
Color

W1209, 10K NTC Cable 100CM, 10K NTC Cable 200CM, W1209 cable